VP Series Double Variable Displacement Vane Pumps combine two variable vane-pump sections into one compact pump body.
The two pump sections share:
One drive shaft
And are usually driven by:
One electric motor
At the same time, the two pump sections can supply oil to different hydraulic circuits separately.
The basic structure can be represented as:
Motor → common drive shaft → front pump + rear pump
Then:
Front pump outlet → hydraulic circuit A
Rear pump outlet → hydraulic circuit B
This structure allows one motor to drive two hydraulic circuits at the same time without installing two completely independent:
Motor + hydraulic pump
Combinations.
VP double variable vane pumps are commonly used in industrial hydraulic systems that require two circuits with different flow rates or different pressure control.
What Is a VP Double Vane Pump
A VP double pump can be simply understood as:
Two variable vane pumps
Combined into:
One tandem pump assembly
The two pump sections share:
One input shaft
And usually share:
One drive motor
But can provide:
Two independent hydraulic outputs
Therefore, the equipment does not need to separately install:
Motor + pump 1
And:
Motor + pump 2
Instead, it can adopt:
One motor + one double pump
To form a more compact hydraulic power structure.
How the Double-Pump Structure Works
When the motor starts:
The motor drives the common drive shaft to rotate
The drive shaft simultaneously drives:
The front pump
And:
The rear pump
Two variable vane-pump sections.
Each pump section usually includes:
Rotor
Vanes
Cam ring
Pressure adjustment mechanism
Flow / displacement adjustment mechanism
When the rotor rotates, the working chamber volume formed between the vanes continuously changes.
In the suction area:
Working chamber volume increases → hydraulic oil enters
In the discharge area:
Working chamber volume decreases → hydraulic oil is forced out
Because the double pump contains two pump sections internally, the two pumps work at the same time.
One Motor Can Drive Two Hydraulic Circuits
One of the biggest features of the VP double pump is:
One power source can supply two different hydraulic functions at the same time.
For example:
Front pump → clamping circuit
Rear pump → feed circuit
Or:
Front pump → main machine circuit
Rear pump → auxiliary hydraulic circuit
This structure can simplify hydraulic station design.
Compared with installing:
Two motors + two hydraulic pumps
A double pump can use:
One motor + one double-pump assembly
Thereby reducing:
Installation space
Number of couplings
Electrical control components
And some mechanical mounting structures.
Front and Rear Pumps Can Be Adjusted Independently
One of the important features of the VP double variable pump is that the two pump sections can have different pressure settings.
Therefore, one double pump may simultaneously have:
Front pump pressure range
And:
Rear pump pressure range
Some common low-pressure VP series pressure adjustment ranges may include:
A1: approx. 0.8–2.5 MPa
A2: approx. 2.0–4.5 MPa
A3: approx. 4.0–7.0 MPa
The specific range needs to be confirmed according to the manufacturer and complete model.
This allows the two hydraulic circuits to work under different pressure conditions.
Why Independent Pressure Adjustment Is Important
Suppose a machine has two hydraulic functions.
The first circuit may require:
Lower pressure + continuous action
While the second circuit may require:
Higher pressure + intermittent clamping
If only one ordinary hydraulic pump is used, the two circuits usually need more:
Relief valves
Pressure reducing valves
Throttle control
To meet different pressure requirements.
A double variable vane pump can use:
Pump A → pressure setting A
Pump B → pressure setting B
This can make the entire hydraulic system more flexible.
Variable Displacement Working Principle
The VP variable vane pump is different from an ordinary fixed displacement vane pump.
It can, according to system pressure changes:
Automatically reduce displacement
The basic working process can be represented as:
When system pressure is low
The cam ring maintains a large eccentricity
↓
Pump displacement is large
↓
More flow is output
When system pressure gradually reaches the set value:
System pressure rises
↓
Hydraulic force pushes the cam ring to move
↓
Eccentricity decreases
↓
Pump displacement decreases
↓
Output flow decreases
After the actuator stops moving, the pump can reduce output and only provide the small flow required for system leakage.
How Variable Pumps Reduce Unnecessary Flow Loss
When the speed remains constant, a fixed displacement pump continuously outputs a nearly fixed flow.
If the hydraulic cylinder stops:
The pump continues to supply oil
Excess flow may pass through:
The relief valve
Back to the tank.
This converts a large amount of hydraulic energy into heat.
A variable vane pump can:
Actuator needs to move → pump increases flow
Actuator stops → pressure rises → pump reduces displacement
Therefore, compared with a fixed displacement pump system that continuously unloads oil through a relief valve, a VP variable vane pump can reduce part of:
Energy loss
And:
Hydraulic system heating
Common VP Double-Pump Models
Common VP double variable vane-pump combinations include:
VP-08-08
VP-12-12
VP-15-15
VP-20-20
VP-25-25
VP-30-30
VP-40-40
Different manufacturers may use different formats, such as:
VP-30-30
VP-3030
Or:
VPP-30/30
Therefore, when replacing, it is best to confirm the model according to:
The original pump complete nameplate
Common VP Double-Pump Flow Reference
For some common low-pressure VP double-pump series at approximately 1800 rpm, common no-load flow combinations may be:
VP-08-08 → approx. 8 + 8 L/min
VP-12-12 → approx. 12 + 12 L/min
VP-15-15 → approx. 15 + 15 L/min
VP-20-20 → approx. 20 + 20 L/min
VP-25-25 → approx. 25 + 25 L/min
VP-30-30 → approx. 30 + 30 L/min
VP-40-40 → approx. 40 + 40 L/min
The common operating speed range for the same type of series is approximately:
800–1800 rpm
The common maximum working pressure is approximately:
7 MPa / 70 bar
The specific value still needs to be confirmed according to the complete model.
How to Understand Front and Rear Pump Flow
The two numbers in a double-pump model usually correspond to the two pump sections.
For example:
VP-30-30
Can be understood as:
The front pump belongs to the VP-30 flow class
At the same time:
The rear pump also belongs to the VP-30 flow class
Therefore, it does not simply mean:
The entire pump is only 30 L/min
Instead, there are:
Two independent hydraulic outputs
This point is very important when replacing a double pump.
The Two Flow Paths Can Be Used Independently
VP double pumps can usually:
Outlet 1 → circuit A
Outlet 2 → circuit B
The two circuits work separately.
Some special hydraulic systems may also combine the two flow paths under certain conditions through:
Check valves
Logic valves
Control valves
However, whether the flows can be combined needs to be judged according to:
The pressure settings of the two pumps
Circuit structure
Check valve configuration
Machine action requirements
It cannot be assumed that the two oil paths can be directly combined just because it is a double pump.
Difference Between VP Double Pump and Single VP Pump
A single VP pump has only:
One variable vane-pump section
And:
One main output
Suitable for:
A single main hydraulic circuit
A double VP pump has:
Two pump sections
And:
Two hydraulic outputs
More suitable for:
Two independent hydraulic circuits
The double structure can reduce:
Number of motors
Number of couplings
Installation space
Hydraulic station structural complexity
Difference Between VP Double Pump and Two Independent Hydraulic Pumps
Using two independent hydraulic pumps can also provide two circuits.
But usually requires:
Two motors
Two couplings
Two mounting bases
Two sets of electrical control
A VP double pump only needs:
One motor
And:
One common drive shaft
Therefore, the hydraulic station can be made more compact.
But it should be noted:
If:
The common motor
Or:
The common drive shaft
Fails, both hydraulic circuits may be affected at the same time.
Difference Between VP Double Pump and High-Low Combination Pump
An ordinary VP double variable vane pump and:
A high-low combination pump
Are not the same product.
Some VP series combination pumps may use:
Low-pressure large-flow variable vane pump
High-pressure small-flow pump
This structure is mainly used for:
Fast low-pressure action + high-pressure working
While an ordinary VP double variable pump is usually:
Two variable vane-pump sections
Combined.
The two differ obviously in:
Pressure
Flow
Control method
Application scenarios
Pressure Rating Must Be Confirmed
VP double pumps usually belong to:
Medium-low pressure variable vane pumps
The common maximum working pressure of low-pressure series is approximately:
7 MPa / 70 bar
Therefore, it is completely different from the following high-pressure hydraulic pumps:
High-pressure piston pumps
High-pressure vane pumps
If the actual working pressure of the equipment requires:
140 bar
210 bar
Or even:
315 bar
Then an ordinary VP double pump cannot be selected simply because the flow is suitable.
Speed Must Match the Motor
The common applicable speed range of VP double pumps is approximately:
800–1800 rpm
Therefore, they are very suitable for:
Industrial motor-driven hydraulic stations
But before installation, the following must still be confirmed:
Actual motor speed
Maximum allowable pump speed
Minimum allowable speed
Motor power
Input shaft compatibility
An arbitrary motor cannot be directly combined with a VP double pump.
Motor Power Must Consider Both Pump Sections
A common selection mistake is:
Calculating the power of only one pump section.
In reality, one motor simultaneously drives:
The front pump
And:
The rear pump
Therefore, the motor must meet the sum of the two hydraulic power requirements.
It can be simply understood as:
Total power requirement ≈ front pump pressure × front pump flow + rear pump pressure × rear pump flow
If both pumps are loaded at the same time:
The motor power requirement will increase significantly.
Therefore, selection must consider:
Whether both circuits work at the same time under the heaviest working condition of the equipment.
Do Both Pumps Always Reach Maximum Pressure at the Same Time?
Not necessarily.
The actual pressure depends on the load of each hydraulic circuit.
For example:
Front pump circuit → 3 MPa
At the same time:
Rear pump circuit → 6 MPa
This is entirely possible.
As long as the two pump sections have independent pressure adjustment and the hydraulic system design is reasonable.
Therefore, actual power calculation should be based on:
The real working cycle
Rather than simply adding the two maximum pressures directly.
Mounting Methods
Common mounting forms of VP double pumps include:
Flange mounting
Some manufacturers may also provide:
Foot mounting
For example, some models may use:
F = flange mounting
Or:
L = foot mounting
When replacing, confirm:
Flange dimensions
Mounting hole positions
Centering spigot
Shaft center height
Do not select only according to flow specification.
Input Shaft Must Match
The common drive shaft of a VP double pump must match the motor coupling.
Need to confirm:
Shaft diameter
Shaft length
Keyway
Spline specification
Shaft shoulder position
Coupling type
Even if two pumps are both marked:
VP-30-30
The shaft dimensions from different manufacturers may also differ.
Therefore, when replacing, both must be confirmed:
Hydraulic parameters
And:
Mechanical dimensions
Suction Port and Two Outlet Ports
VP double pumps usually have:
Suction port
Front pump outlet
Rear pump outlet
And:
Drain port
The specific structure varies by manufacturer.
The two outlet ports must be correctly identified.
If the two outlets are connected in reverse, it may cause:
Abnormal equipment action
Mismatched pressure setting
Wrong flow
Wrong action sequence
Therefore, before removing the old pump, it is recommended to:
Mark each hose.
Drain Line Is Very Important
Variable vane pumps usually require a drain line for:
Internal leakage oil
And:
Return oil from the variable control mechanism
The drain line should generally:
Return to the tank at low back pressure
If the drain back pressure is too high, it may affect:
Variable mechanism action
Shaft seal
Internal leakage
Pump body temperature
Therefore, it is not recommended to connect the drain line arbitrarily to a high-back-pressure return line.
Suction Conditions Must Be Good
All hydraulic pumps require sufficient suction.
If suction conditions are poor, the following may occur:
Cavitation
Abnormal noise
Unstable flow
Reduced pump life
Common causes include:
Suction pipe too small
Suction strainer blocked
Oil tank level too low
Hydraulic oil temperature too low
Suction pipe too long
Air drawn in at fittings
Because there are two pump sections working simultaneously inside a double pump, suction capability needs to be ensured even more.
Precautions for Initial Startup
After installing a new VP double pump, it is not recommended to immediately operate at full load.
Before startup, confirm:
Correct rotation direction
Sufficient oil tank level
Correct suction port connection
Correct connection of the two outlet ports
Correct drain line connection
Normal pump-motor alignment
Then first operate under:
Low load
Or:
No load
This helps discharge:
Air inside the pump
And:
Air in the suction line
Reducing damage during initial startup.
Hydraulic Oil Temperature and Viscosity
Hydraulic oil viscosity affects:
Lubrication
Internal leakage
Suction performance
Pressure adjustment
When oil temperature is too low:
Viscosity too high → suction resistance increases
When oil temperature is too high:
Viscosity decreases → internal leakage increases
The common continuous working oil temperature reference for some VP series is approximately:
15–60°C
But different brands and models will differ.
Therefore, the final value should be determined according to the specific pump technical data.
Low-Noise Operating Characteristics
Because variable vane pumps have a relatively large number of working chambers, the output flow is relatively smooth.
Common features include:
Smaller flow pulsation
Lower operating noise
Smoother oil output
This makes the VP series very suitable for:
Machine tools
Automation equipment
Indoor hydraulic stations
And other occasions that are sensitive to noise.
A double VP pump can provide power for two circuits while maintaining relatively low noise.
Typical Application: Machine Tools
Machine tools often require multiple hydraulic functions.
For example:
Circuit A → workpiece clamping
Circuit B → worktable feed
Or:
Circuit B → auxiliary hydraulic action
A VP double pump can simultaneously meet the needs of two circuits through one hydraulic station.
And the two pump sections can be set separately according to the actual equipment requirements:
Pressure
And:
Flow
Typical Application: Hydraulic Clamping
Some equipment may require:
One low-pressure continuous oil circuit
At the same time:
Another clamping oil circuit with a different pressure
A double pump can let:
One pump section be dedicated to clamping
The other pump section handle other actions
This can reduce the use of a large amount of:
Throttling
And:
Pressure reduction
To forcibly match two different circuits.
Typical Application: Industrial Automation
Automation equipment may have multiple hydraulic actuators at the same time.
A double pump can separately supply:
Main action circuit
And:
Auxiliary control circuit
The two circuits can work relatively independently.
This helps:
Simplify the hydraulic station
While maintaining independent control between different functions.
Typical Application: Hydraulic Power Units
Compact hydraulic stations attach great importance to:
Space
Number of motors
Installation complexity
A VP double pump uses one motor to drive two pump sections, which can reduce:
A second motor
A second motor mounting base
A second coupling
Thereby making the hydraulic power unit more compact.
Common Faults of VP Double Pumps
Both pump sections have insufficient flow
Possible causes:
Insufficient motor speed
Poor suction
Wrong rotation direction
Air in the oil
Common drive shaft fault
Only one pump section has insufficient flow
Possible causes:
Incorrect flow adjustment
Wear of one pump cartridge
Variable mechanism fault
Leakage in the corresponding hydraulic circuit
Pump cannot reach the set pressure
Possible causes:
Pressure setting too low
Internal wear
Wrong system relief valve setting
Hydraulic system leakage
Loud hydraulic pump noise
Possible causes:
Cavitation
Air entering the suction pipe
Coupling misalignment
Improper hydraulic oil viscosity
Pump temperature too high
Possible causes:
Long-term high-pressure operation
Excessive internal leakage
Unsuitable hydraulic oil
Insufficient cooling
Motor overload
If One Pump Works Normally and the Other Does Not, How to Check
When a double pump fails, the two pump sections should be tested separately.
Measure separately:
Front pump outlet pressure
And:
Rear pump outlet pressure
Then check separately:
Flow setting
Pressure setting
Corresponding circuit load
System leakage
This can determine whether the fault comes from:
The pump itself
Or:
The connected hydraulic circuit
Contamination Control
VP variable vane pumps internally include:
Vanes
Cam ring
Variable control mechanism
And other precision moving parts.
Contamination may cause:
Vane wear
Cam ring wear
Variable mechanism sticking
Unstable pressure
Flow decrease
Increased noise
Therefore, use:
A suitable hydraulic filtration system
And keep the oil clean.
If the old pump has already suffered severe internal wear, before installing a new pump:
Clean the hydraulic system
Do Not Replace a Double Pump Only by Appearance
Two double pumps may look very similar in appearance, but their internal parameters may be completely different.
Need to confirm:
Front pump flow
Rear pump flow
Front pump pressure
Rear pump pressure
Mounting method
Input shaft
Port positions
Rotation direction
Therefore:
Same appearance ≠ fully replaceable
How to Read a VP Double-Pump Model
Some models may be written as:
VP-30-30F-A2-A3
Or:
VP3030F-A2-A3
Different manufacturers have different naming methods.
Generally, it may indicate:
VP → product series
30-30 → front pump / rear pump flow class
F → flange mounting
A2 → pressure range of one pump section
A3 → pressure range of the other pump section
But:
The order of pressure codes
And:
Suffix definitions
Must be confirmed according to the specific manufacturer’s model rules.
What to Confirm When Replacing a VP Double Pump
Before ordering, it is recommended to confirm:
Complete original model
Front pump flow
Rear pump flow
Front pump pressure range
Rear pump pressure range
Working speed
Rotation direction
Input shaft
Mounting method
Suction port
Two outlet ports
Drain port
Hydraulic oil
Equipment application
Simply providing:
“VP double pump”
Is usually not enough for accurate selection.
VP Double-Pump Selection Checklist
Correct selection should first confirm:
How much flow the front pump needs
And:
How much flow the rear pump needs
Then confirm:
How much pressure each of the two pumps needs
Then continue to check:
Motor speed
Total motor power
Rotation direction
Input shaft
Mounting dimensions
Port layout
Drain
And:
Equipment working cycle
Therefore, the correct replacement of a VP double pump must simultaneously satisfy:
Hydraulic compatibility
And:
Mechanical installation compatibility
How XYIYEYA Supports VP Double-Pump Replacement
XYIYEYA provides hydraulic vane pumps and other hydraulic power products for industrial machinery, hydraulic power units, maintenance, OEM, and replacement projects.
Related pump products include:
If the customer needs a VP double vane pump, it is recommended to provide:
Original model + nameplate + front/rear pump flow + front/rear pump pressure + speed + rotation direction + input shaft + mounting method + port photos
This allows the specifications of both pump sections to be confirmed before quotation and shipment.
Conclusion
VP series double variable displacement vane pumps combine two variable vane-pump sections through one common drive shaft.
Their main features include:
Two hydraulic outputs
One common motor
Compact structure
Independent circuit supply
Adjustable pressure
Variable displacement
Relatively low operating noise
Common models include:
VP-08-08
VP-12-12
VP-15-15
VP-20-20
VP-25-25
VP-30-30
VP-40-40
The maximum pressure of some common low-pressure series is approximately:
7 MPa / 70 bar
Depending on:
Brand + model + configuration
The most important items to confirm when replacing a VP double pump are:
Front pump flow + rear pump flow + front pump pressure + rear pump pressure + speed + rotation direction + input shaft + mounting + ports
If correctly selected, a VP double variable vane pump can provide stable and reliable hydraulic power for two hydraulic circuits through one compact power source.