News Center

Home » Industry News » VP Series Double Variable Displacement Vane Pumps for Dual-Circuit Hydraulic Systems

VP Series Double Variable Displacement Vane Pumps for Dual-Circuit Hydraulic Systems

VP Series Double Variable Displacement Vane Pumps combine two variable vane-pump sections into one compact pump body.

The two pump sections share:

One drive shaft

And are usually driven by:

One electric motor

At the same time, the two pump sections can supply oil to different hydraulic circuits separately.

The basic structure can be represented as:

Motor → common drive shaft → front pump + rear pump

Then:

Front pump outlet → hydraulic circuit A

Rear pump outlet → hydraulic circuit B

This structure allows one motor to drive two hydraulic circuits at the same time without installing two completely independent:

Motor + hydraulic pump

Combinations.

VP double variable vane pumps are commonly used in industrial hydraulic systems that require two circuits with different flow rates or different pressure control.

What Is a VP Double Vane Pump

A VP double pump can be simply understood as:

Two variable vane pumps

Combined into:

One tandem pump assembly

The two pump sections share:

One input shaft

And usually share:

One drive motor

But can provide:

Two independent hydraulic outputs

Therefore, the equipment does not need to separately install:

Motor + pump 1

And:

Motor + pump 2

Instead, it can adopt:

One motor + one double pump

To form a more compact hydraulic power structure.

How the Double-Pump Structure Works

When the motor starts:

The motor drives the common drive shaft to rotate

The drive shaft simultaneously drives:

The front pump

And:

The rear pump

Two variable vane-pump sections.

Each pump section usually includes:

Rotor

Vanes

Cam ring

Pressure adjustment mechanism

Flow / displacement adjustment mechanism

When the rotor rotates, the working chamber volume formed between the vanes continuously changes.

In the suction area:

Working chamber volume increases → hydraulic oil enters

In the discharge area:

Working chamber volume decreases → hydraulic oil is forced out

Because the double pump contains two pump sections internally, the two pumps work at the same time.

One Motor Can Drive Two Hydraulic Circuits

One of the biggest features of the VP double pump is:

One power source can supply two different hydraulic functions at the same time.

For example:

Front pump → clamping circuit

Rear pump → feed circuit

Or:

Front pump → main machine circuit

Rear pump → auxiliary hydraulic circuit

This structure can simplify hydraulic station design.

Compared with installing:

Two motors + two hydraulic pumps

A double pump can use:

One motor + one double-pump assembly

Thereby reducing:

Installation space

Number of couplings

Electrical control components

And some mechanical mounting structures.

Front and Rear Pumps Can Be Adjusted Independently

One of the important features of the VP double variable pump is that the two pump sections can have different pressure settings.

Therefore, one double pump may simultaneously have:

Front pump pressure range

And:

Rear pump pressure range

Some common low-pressure VP series pressure adjustment ranges may include:

A1: approx. 0.8–2.5 MPa

A2: approx. 2.0–4.5 MPa

A3: approx. 4.0–7.0 MPa

The specific range needs to be confirmed according to the manufacturer and complete model.

This allows the two hydraulic circuits to work under different pressure conditions.

Why Independent Pressure Adjustment Is Important

Suppose a machine has two hydraulic functions.

The first circuit may require:

Lower pressure + continuous action

While the second circuit may require:

Higher pressure + intermittent clamping

If only one ordinary hydraulic pump is used, the two circuits usually need more:

Relief valves

Pressure reducing valves

Throttle control

To meet different pressure requirements.

A double variable vane pump can use:

Pump A → pressure setting A

Pump B → pressure setting B

This can make the entire hydraulic system more flexible.

Variable Displacement Working Principle

The VP variable vane pump is different from an ordinary fixed displacement vane pump.

It can, according to system pressure changes:

Automatically reduce displacement

The basic working process can be represented as:

When system pressure is low

The cam ring maintains a large eccentricity

↓

Pump displacement is large

↓

More flow is output

When system pressure gradually reaches the set value:

System pressure rises

↓

Hydraulic force pushes the cam ring to move

↓

Eccentricity decreases

↓

Pump displacement decreases

↓

Output flow decreases

After the actuator stops moving, the pump can reduce output and only provide the small flow required for system leakage.

How Variable Pumps Reduce Unnecessary Flow Loss

When the speed remains constant, a fixed displacement pump continuously outputs a nearly fixed flow.

If the hydraulic cylinder stops:

The pump continues to supply oil

Excess flow may pass through:

The relief valve

Back to the tank.

This converts a large amount of hydraulic energy into heat.

A variable vane pump can:

Actuator needs to move → pump increases flow

Actuator stops → pressure rises → pump reduces displacement

Therefore, compared with a fixed displacement pump system that continuously unloads oil through a relief valve, a VP variable vane pump can reduce part of:

Energy loss

And:

Hydraulic system heating

Common VP Double-Pump Models

Common VP double variable vane-pump combinations include:

VP-08-08

VP-12-12

VP-15-15

VP-20-20

VP-25-25

VP-30-30

VP-40-40

Different manufacturers may use different formats, such as:

VP-30-30

VP-3030

Or:

VPP-30/30

Therefore, when replacing, it is best to confirm the model according to:

The original pump complete nameplate

Common VP Double-Pump Flow Reference

For some common low-pressure VP double-pump series at approximately 1800 rpm, common no-load flow combinations may be:

VP-08-08 → approx. 8 + 8 L/min

VP-12-12 → approx. 12 + 12 L/min

VP-15-15 → approx. 15 + 15 L/min

VP-20-20 → approx. 20 + 20 L/min

VP-25-25 → approx. 25 + 25 L/min

VP-30-30 → approx. 30 + 30 L/min

VP-40-40 → approx. 40 + 40 L/min

The common operating speed range for the same type of series is approximately:

800–1800 rpm

The common maximum working pressure is approximately:

7 MPa / 70 bar

The specific value still needs to be confirmed according to the complete model.

How to Understand Front and Rear Pump Flow

The two numbers in a double-pump model usually correspond to the two pump sections.

For example:

VP-30-30

Can be understood as:

The front pump belongs to the VP-30 flow class

At the same time:

The rear pump also belongs to the VP-30 flow class

Therefore, it does not simply mean:

The entire pump is only 30 L/min

Instead, there are:

Two independent hydraulic outputs

This point is very important when replacing a double pump.

The Two Flow Paths Can Be Used Independently

VP double pumps can usually:

Outlet 1 → circuit A

Outlet 2 → circuit B

The two circuits work separately.

Some special hydraulic systems may also combine the two flow paths under certain conditions through:

Check valves

Logic valves

Control valves

However, whether the flows can be combined needs to be judged according to:

The pressure settings of the two pumps

Circuit structure

Check valve configuration

Machine action requirements

It cannot be assumed that the two oil paths can be directly combined just because it is a double pump.

Difference Between VP Double Pump and Single VP Pump

A single VP pump has only:

One variable vane-pump section

And:

One main output

Suitable for:

A single main hydraulic circuit

A double VP pump has:

Two pump sections

And:

Two hydraulic outputs

More suitable for:

Two independent hydraulic circuits

The double structure can reduce:

Number of motors

Number of couplings

Installation space

Hydraulic station structural complexity

Difference Between VP Double Pump and Two Independent Hydraulic Pumps

Using two independent hydraulic pumps can also provide two circuits.

But usually requires:

Two motors

Two couplings

Two mounting bases

Two sets of electrical control

A VP double pump only needs:

One motor

And:

One common drive shaft

Therefore, the hydraulic station can be made more compact.

But it should be noted:

If:

The common motor

Or:

The common drive shaft

Fails, both hydraulic circuits may be affected at the same time.

Difference Between VP Double Pump and High-Low Combination Pump

An ordinary VP double variable vane pump and:

A high-low combination pump

Are not the same product.

Some VP series combination pumps may use:

Low-pressure large-flow variable vane pump

High-pressure small-flow pump

This structure is mainly used for:

Fast low-pressure action + high-pressure working

While an ordinary VP double variable pump is usually:

Two variable vane-pump sections

Combined.

The two differ obviously in:

Pressure

Flow

Control method

Application scenarios

Pressure Rating Must Be Confirmed

VP double pumps usually belong to:

Medium-low pressure variable vane pumps

The common maximum working pressure of low-pressure series is approximately:

7 MPa / 70 bar

Therefore, it is completely different from the following high-pressure hydraulic pumps:

High-pressure piston pumps

High-pressure vane pumps

If the actual working pressure of the equipment requires:

140 bar

210 bar

Or even:

315 bar

Then an ordinary VP double pump cannot be selected simply because the flow is suitable.

Speed Must Match the Motor

The common applicable speed range of VP double pumps is approximately:

800–1800 rpm

Therefore, they are very suitable for:

Industrial motor-driven hydraulic stations

But before installation, the following must still be confirmed:

Actual motor speed

Maximum allowable pump speed

Minimum allowable speed

Motor power

Input shaft compatibility

An arbitrary motor cannot be directly combined with a VP double pump.

Motor Power Must Consider Both Pump Sections

A common selection mistake is:

Calculating the power of only one pump section.

In reality, one motor simultaneously drives:

The front pump

And:

The rear pump

Therefore, the motor must meet the sum of the two hydraulic power requirements.

It can be simply understood as:

Total power requirement ≈ front pump pressure × front pump flow + rear pump pressure × rear pump flow

If both pumps are loaded at the same time:

The motor power requirement will increase significantly.

Therefore, selection must consider:

Whether both circuits work at the same time under the heaviest working condition of the equipment.

Do Both Pumps Always Reach Maximum Pressure at the Same Time?

Not necessarily.

The actual pressure depends on the load of each hydraulic circuit.

For example:

Front pump circuit → 3 MPa

At the same time:

Rear pump circuit → 6 MPa

This is entirely possible.

As long as the two pump sections have independent pressure adjustment and the hydraulic system design is reasonable.

Therefore, actual power calculation should be based on:

The real working cycle

Rather than simply adding the two maximum pressures directly.

Mounting Methods

Common mounting forms of VP double pumps include:

Flange mounting

Some manufacturers may also provide:

Foot mounting

For example, some models may use:

F = flange mounting

Or:

L = foot mounting

When replacing, confirm:

Flange dimensions

Mounting hole positions

Centering spigot

Shaft center height

Do not select only according to flow specification.

Input Shaft Must Match

The common drive shaft of a VP double pump must match the motor coupling.

Need to confirm:

Shaft diameter

Shaft length

Keyway

Spline specification

Shaft shoulder position

Coupling type

Even if two pumps are both marked:

VP-30-30

The shaft dimensions from different manufacturers may also differ.

Therefore, when replacing, both must be confirmed:

Hydraulic parameters

And:

Mechanical dimensions

Suction Port and Two Outlet Ports

VP double pumps usually have:

Suction port

Front pump outlet

Rear pump outlet

And:

Drain port

The specific structure varies by manufacturer.

The two outlet ports must be correctly identified.

If the two outlets are connected in reverse, it may cause:

Abnormal equipment action

Mismatched pressure setting

Wrong flow

Wrong action sequence

Therefore, before removing the old pump, it is recommended to:

Mark each hose.

Drain Line Is Very Important

Variable vane pumps usually require a drain line for:

Internal leakage oil

And:

Return oil from the variable control mechanism

The drain line should generally:

Return to the tank at low back pressure

If the drain back pressure is too high, it may affect:

Variable mechanism action

Shaft seal

Internal leakage

Pump body temperature

Therefore, it is not recommended to connect the drain line arbitrarily to a high-back-pressure return line.

Suction Conditions Must Be Good

All hydraulic pumps require sufficient suction.

If suction conditions are poor, the following may occur:

Cavitation

Abnormal noise

Unstable flow

Reduced pump life

Common causes include:

Suction pipe too small

Suction strainer blocked

Oil tank level too low

Hydraulic oil temperature too low

Suction pipe too long

Air drawn in at fittings

Because there are two pump sections working simultaneously inside a double pump, suction capability needs to be ensured even more.

Precautions for Initial Startup

After installing a new VP double pump, it is not recommended to immediately operate at full load.

Before startup, confirm:

Correct rotation direction

Sufficient oil tank level

Correct suction port connection

Correct connection of the two outlet ports

Correct drain line connection

Normal pump-motor alignment

Then first operate under:

Low load

Or:

No load

This helps discharge:

Air inside the pump

And:

Air in the suction line

Reducing damage during initial startup.

Hydraulic Oil Temperature and Viscosity

Hydraulic oil viscosity affects:

Lubrication

Internal leakage

Suction performance

Pressure adjustment

When oil temperature is too low:

Viscosity too high → suction resistance increases

When oil temperature is too high:

Viscosity decreases → internal leakage increases

The common continuous working oil temperature reference for some VP series is approximately:

15–60°C

But different brands and models will differ.

Therefore, the final value should be determined according to the specific pump technical data.

Low-Noise Operating Characteristics

Because variable vane pumps have a relatively large number of working chambers, the output flow is relatively smooth.

Common features include:

Smaller flow pulsation

Lower operating noise

Smoother oil output

This makes the VP series very suitable for:

Machine tools

Automation equipment

Indoor hydraulic stations

And other occasions that are sensitive to noise.

A double VP pump can provide power for two circuits while maintaining relatively low noise.

Typical Application: Machine Tools

Machine tools often require multiple hydraulic functions.

For example:

Circuit A → workpiece clamping

Circuit B → worktable feed

Or:

Circuit B → auxiliary hydraulic action

A VP double pump can simultaneously meet the needs of two circuits through one hydraulic station.

And the two pump sections can be set separately according to the actual equipment requirements:

Pressure

And:

Flow

Typical Application: Hydraulic Clamping

Some equipment may require:

One low-pressure continuous oil circuit

At the same time:

Another clamping oil circuit with a different pressure

A double pump can let:

One pump section be dedicated to clamping

The other pump section handle other actions

This can reduce the use of a large amount of:

Throttling

And:

Pressure reduction

To forcibly match two different circuits.

Typical Application: Industrial Automation

Automation equipment may have multiple hydraulic actuators at the same time.

A double pump can separately supply:

Main action circuit

And:

Auxiliary control circuit

The two circuits can work relatively independently.

This helps:

Simplify the hydraulic station

While maintaining independent control between different functions.

Typical Application: Hydraulic Power Units

Compact hydraulic stations attach great importance to:

Space

Number of motors

Installation complexity

A VP double pump uses one motor to drive two pump sections, which can reduce:

A second motor

A second motor mounting base

A second coupling

Thereby making the hydraulic power unit more compact.

Common Faults of VP Double Pumps

Both pump sections have insufficient flow

Possible causes:

Insufficient motor speed

Poor suction

Wrong rotation direction

Air in the oil

Common drive shaft fault

Only one pump section has insufficient flow

Possible causes:

Incorrect flow adjustment

Wear of one pump cartridge

Variable mechanism fault

Leakage in the corresponding hydraulic circuit

Pump cannot reach the set pressure

Possible causes:

Pressure setting too low

Internal wear

Wrong system relief valve setting

Hydraulic system leakage

Loud hydraulic pump noise

Possible causes:

Cavitation

Air entering the suction pipe

Coupling misalignment

Improper hydraulic oil viscosity

Pump temperature too high

Possible causes:

Long-term high-pressure operation

Excessive internal leakage

Unsuitable hydraulic oil

Insufficient cooling

Motor overload

If One Pump Works Normally and the Other Does Not, How to Check

When a double pump fails, the two pump sections should be tested separately.

Measure separately:

Front pump outlet pressure

And:

Rear pump outlet pressure

Then check separately:

Flow setting

Pressure setting

Corresponding circuit load

System leakage

This can determine whether the fault comes from:

The pump itself

Or:

The connected hydraulic circuit

Contamination Control

VP variable vane pumps internally include:

Vanes

Cam ring

Variable control mechanism

And other precision moving parts.

Contamination may cause:

Vane wear

Cam ring wear

Variable mechanism sticking

Unstable pressure

Flow decrease

Increased noise

Therefore, use:

A suitable hydraulic filtration system

And keep the oil clean.

If the old pump has already suffered severe internal wear, before installing a new pump:

Clean the hydraulic system

Do Not Replace a Double Pump Only by Appearance

Two double pumps may look very similar in appearance, but their internal parameters may be completely different.

Need to confirm:

Front pump flow

Rear pump flow

Front pump pressure

Rear pump pressure

Mounting method

Input shaft

Port positions

Rotation direction

Therefore:

Same appearance ≠ fully replaceable

How to Read a VP Double-Pump Model

Some models may be written as:

VP-30-30F-A2-A3

Or:

VP3030F-A2-A3

Different manufacturers have different naming methods.

Generally, it may indicate:

VP → product series

30-30 → front pump / rear pump flow class

F → flange mounting

A2 → pressure range of one pump section

A3 → pressure range of the other pump section

But:

The order of pressure codes

And:

Suffix definitions

Must be confirmed according to the specific manufacturer’s model rules.

What to Confirm When Replacing a VP Double Pump

Before ordering, it is recommended to confirm:

Complete original model

Front pump flow

Rear pump flow

Front pump pressure range

Rear pump pressure range

Working speed

Rotation direction

Input shaft

Mounting method

Suction port

Two outlet ports

Drain port

Hydraulic oil

Equipment application

Simply providing:

“VP double pump”

Is usually not enough for accurate selection.

VP Double-Pump Selection Checklist

Correct selection should first confirm:

How much flow the front pump needs

And:

How much flow the rear pump needs

Then confirm:

How much pressure each of the two pumps needs

Then continue to check:

Motor speed

Total motor power

Rotation direction

Input shaft

Mounting dimensions

Port layout

Drain

And:

Equipment working cycle

Therefore, the correct replacement of a VP double pump must simultaneously satisfy:

Hydraulic compatibility

And:

Mechanical installation compatibility

How XYIYEYA Supports VP Double-Pump Replacement

XYIYEYA provides hydraulic vane pumps and other hydraulic power products for industrial machinery, hydraulic power units, maintenance, OEM, and replacement projects.

Related pump products include:

VP variable vane pumps

VP double variable vane pumps

High-low combination pumps

PFE vane pumps

PV2R vane pumps

Gear pumps

Axial piston pumps

If the customer needs a VP double vane pump, it is recommended to provide:

Original model + nameplate + front/rear pump flow + front/rear pump pressure + speed + rotation direction + input shaft + mounting method + port photos

This allows the specifications of both pump sections to be confirmed before quotation and shipment.

Conclusion

VP series double variable displacement vane pumps combine two variable vane-pump sections through one common drive shaft.

Their main features include:

Two hydraulic outputs

One common motor

Compact structure

Independent circuit supply

Adjustable pressure

Variable displacement

Relatively low operating noise

Common models include:

VP-08-08

VP-12-12

VP-15-15

VP-20-20

VP-25-25

VP-30-30

VP-40-40

The maximum pressure of some common low-pressure series is approximately:

7 MPa / 70 bar

Depending on:

Brand + model + configuration

The most important items to confirm when replacing a VP double pump are:

Front pump flow + rear pump flow + front pump pressure + rear pump pressure + speed + rotation direction + input shaft + mounting + ports

If correctly selected, a VP double variable vane pump can provide stable and reliable hydraulic power for two hydraulic circuits through one compact power source.

滚动至顶部